IOX-COLD and IOX-COLD RUGGED — Thermograph Solution Installation Guide
The connection to a thermograph is achieved using the harness HRN-CCTH (IOX-COLD) or HRN-RCCTH (IOX-COLD RUGGED).

Support Document

7 mins to read

In this document

Thermograph Solution Installation Guide

Introduction

The connection to a thermograph is achieved using the harness HRN-CCTH (IOX-COLD) or HRN-RCCTH (IOX-COLD RUGGED). Their loose wires are directly connected to the thermograph’s screw terminal connectors or crimped to the thermograph’s connectors. The pinout on the thermograph’s side, depends on its brand and model. For more information, please see Thermograph Specifications and Configurations section.

! IMPORTANT: Once the required installations between the IOX-COLD/IOX-COLD RUGGED and its compatible solutions (Refrigeration unit and accessories, Thermograph, Tachograph, Expansions) have been completed, the IOX-COLD/IOX-COLD RUGGED must be installed with GO9/GO9 RUGGED devices as outlined in the quick start guides.

Access to the quick start guide documents here :

  1. IOX-COLD: gtb.link/ioxcold
  2. IOX-COLD RUGGED: gtb.link/ioxcoldrugged

IOX-COLD

Typical installation connection schematic

document Image

Preparing for installation

Tools

Ensure that you have all of the following:

  1. Screwdriver kit
  2. Cable guide
  3. Cutter plier
  4. Gripping plier
  5. Tachograph/Thermograph extractor keys
  6. Cable ties
  7. Components

  8. Product

    Reference

    Quantity

    IOX-COLD

    IOX-COLD

    1

    Thermograph interface harness

    HRN-CCTH

    1

  9. Installation instructions

  10. NOTE: To connect the IOX-COLD to a thermograph, use the loose wire of the harness HRN-CCTH.

  11. 1

    Remove the Thermograph from its location using extractors.

    document Image

    document Image

    2

    Connect the HRN-CCTH to the IOX-COLD.

    document Image

    3

    Route the harness HRN-CCTH. If needed, cut or loop its extra length after having routed the harness.

    Once routed, connect the harness to the Thermograph following the connection table below and the Thermograph specifications and configurations section.

    document Image

    document Image

  12. HRN-CCTH Loose wires

    Thermograph

    Signal

    Wire color

    Signal

    RS232-RX

    Turquoise

    RS232-TX

    RS232-TX

    Purple

    RS232-RX

    GND

    Black

    GND

  13. 4

    Place the Thermograph back in its original location.

    document Image


  14. IOX-COLD RUGGED

  15. Typical installation connection schematic

  16. document Image

  17. Preparing for installation

  18. Tools

  19. Ensure that you have all of the following:

  20. Screwdriver kit
  21. Ratchet kit
  1. Cable guide
  2. Cutter plier
  3. Gripping plier
  4. Cable ties

Components

Product

Reference

Quantity

IOX-COLD

IOX-COLD

1

Thermograph interface harness

HRN-RCCTH

1

Installation instructions

1

Open the Thermograph compartment by removing the four screws.

document Image

2

Cut the extra length of the Thermograph cable and insert the cable in the Thermograph box.

document Image

3

Connect the IOX-COLD RUGGED to the Thermograph following the connection table below and the Thermograph specifications and configurations section.

document Image

HRN-RCCTH Loose wires

Thermograph

Signal

Wire color

Signal

RS232-RX

Turquoise

RS232-TX

RS232-TX

Purple

RS232-RX

GND

Black

GND

4

Close and secure the Thermograph compartment using the four screws.

document Image

Appendix

Thermograph specifications and configurations

ThermoKing TKDL - PRO/SPR/DCS

Image of Thermoking

Connections

Configuration

Thermoking connectors

No configuration is required.

If the equipment does not receive information from the thermograph, you can check port speed by accessing the Configuration Menu:

  1. Press the blue and red button together until Enter PIN code is displayed. Press the blue button 4 times (pin code 1111). Use the red button to scroll through the options.
  2. Option ENG Display > OFF must be set to ON moving the cursor with the ◄ and ► keys.
  3. Continue scrolling through options until you find Baud Rate > 9600. Value must be 9600, otherwise adjust it moving with the ◄ and ► keys and adjusting with the ▲ and ▼ keys.

TX (2)

RX (3)

GND (1)

Cold Chain instruments Transcan - 2ADR/Sentinel

Image of Transcan

Connections

Configuration

Same as Thermo King

Not required, or same as Thermo King

Cold Chain instruments Transcan - Advance

Image of Transcan AdvanceImage of Transcan AdvanceImage of Transcan Advance

Connections

Configuration

Same as Thermo King

Not required, or same as Thermo King

Carrier Datacold - 250/300/500

Image of Carrier Datacold 500

Connections

Configuration

Carrier Datacold 500 connectors

  1. Press the green button for three seconds. Enter Pin code is displayed.
  2. Enter "1111" with the blue button. Set temperature inputs are displayed.
  3. Choose the communication menu with the blue button. 11.2 COM 2 Port Settings is displayed.
  4. Select Third party with the yellow or blue button.
  5. Confirm your selection with the green button.
  6. Press the red button twice to exit and switch to the main menu.

CON2 TX

CON2 RX

CON1 -

Carrier Datacold - 600

Image of Carrier Datacold 600

Connections

Configuration

Carrier Datacold 600 connectors

  1. Press the green button for 4 seconds. Enter Pin code is displayed.
  2. Enter 1111 with the blue button.
  3. Choose the communication menu with the blue button.
  4. Select COM1 or COM2 configuration depending on connection. 11.1 COM 1 Port Settings is displayed.
  5. Select default value, UCP Protocol, with the yellow or blue button.
  6. Confirm your selection with the green button.
  7. Press the red button twice to exit and switch to the main menu.

CON2 TX

CON2 RX

CON1 -

Euroscan - X1/X2


Connections

Configuration

Same as Carrier Datacold 500

  1. Press the green button for three seconds. Enter Pin code appears on the display.
  2. Enter 1111 with the blue button. Set temperature inputs are displayed.
  3. Move down the parameters settings with the yellow button.
  4. Choose the communication menu with the blue button. 11.2 COM 2 Port Settings is displayed.
  5. Select TMS protocol 9k6 with the yellow or blue button, otherwise choose Old ES protocol.
  6. NOTE: TMS protocol 9k6 activates protocol to extract all data. Old ES protocol activates the Thermo King protocol.

  7. Confirm selection with the green button. Press the red button twice to exit and switch to the main menu.

Orbcomm - Euroscan X3

Image of Euroscan X3

Connections

Configuration

Same as Carrier Datacold 600

Same as Carrier Datacold 600

Apache - Cold Tracer

Connections

Configuration

Version Requirement

Apache Cold Tracer connectors

No configuration is required.

FW version 0.5.28 or later is required for Apache Cold Tracer support.

TX (4, blue)

RX (5, cyan)

GND (10, gray)

ThermoKing - TouchLog/TouchPrint

Image of TouchPrint

Connections

Configuration

TouchPrint connectors

  1. Access Service Menu by pressing this key for more than 2 seconds.This menu is password protected. The default password is 10320.
  2. Press the arrow pointing to the right to enter the password.
  3. Click the arrows pointing up and down to enter each number. Click the arrow pointing to the right to move to another.
  4. Press Enter to finish.
  5. Line drawing of Touchprint interface

  6. Once the password is validated, press the arrows pointing up or down to navigate between screens. Go to S1 Serial Port 1 configuration and make sure this is the configuration:
  1. PROTO = MODBUS, ADDRESS=1
  2. BAUD=9600, PARITY=N, STOP BIT=1

Configured ports on Touchprint

TX1 (13)

RX1 (12)

-(1)

Check and update firmware version

! IMPORTANT:It is necessary to upgrade the firmware of the thermographs with firmware version lower than 515.026. Check the version from the main screen.

Thermograph interface displaying firmware version

NOTE: If it is necessary to upgrade the firmware, please contact Support.

Process to update firmware version on Thermograph

Grupo Buscalia - Termotrans

Connections

Configuration

document Image

No configuration is required.

TX (2)

RX (3)

GND (4)


Made Sistemi - REC96

Connections

Configuration

document Image

No configuration is required.

TX (5)

RX (4)

GND (2)

Important safety information and limitations of use

WARNING! Do not attempt to install, configure or remove any product from any vehicle while the vehicle is in motion or otherwise in operation. All installation, configuration or removal must be done only in stationary vehicles which are securely parked. Attempting to service units while being operated could cause malfunctions or accidents, leading to death or serious personal injury.

WARNING! All in-vehicle devices and related cabling must be securely fastened and kept clear of all vehicle controls, including accelerator, brake and clutch pedals. You must inspect devices and cabling on a regular basis to ensure that all devices and cabling continue to be securely attached. Loose cabling or devices may impede the use of vehicle controls, resulting in unanticipated acceleration, braking or other loss of vehicle control, which could lead to death or serious personal injury. Improperly fastened in-vehicle devices may detach and impact operators upon sudden acceleration or deceleration, which may cause injury.

WARNING! If, at any point after an in-vehicle device is installed, a warning light illuminates on the vehicle dashboard or the vehicle stalls or has a marked drop in performance, shut off the engine, remove the device and contact your reseller. Continuing to operate a vehicle with these symptoms can cause loss of vehicle control and serious injury.

WARNING! Your in-vehicle devices must be kept clear of debris, water and other environmental contaminants. Failure to do so may cause units malfunctioning or short-circuiting, which can lead to a fire hazard or vehicle damage or serious injury.

WARNING! Do not attempt to remove the devices from the vehicle they were originally installed in for installation in another vehicle. Not all vehicles share compatibility, and doing so may cause unexpected interactions with your vehicle, including sudden loss of power or shutdown of the vehicle's engine while in operation or cause your vehicle to operate poorly or erratically and cause death or serious injury and/or vehicle damage.

NOTICE: This product does not contain any user-serviceable parts. Configuration, servicing and repairs must only be made by an authorized Reseller or installer. Unauthorized servicing of these products will void your product warranty.